A91-SSD_EU-EN
DRILLING | Structural Steel SoluƟons | T-A® and GEN2 T-A® Replaceable Insert Drills
Recommended Cuƫng Data | Metric (mm)
T-A® | GEN2 T-A®
A
DRILLING
Thin Wall Inserts Super Cobalt
Speed (M/min) - Mist Coolant
Feed Rate (mm/rev) by Diameter
0 series 3 series (12.98 mm - 17.67 mm) (17.53 mm - 24.40 mm) (24.41 mm - 35.06 mm) (34.37 mm - 47.82 mm) 1 series 2 series
Hardness (BHN) 100 - 150 150 - 250 250 - 350
ISO Material
AM200® Speed TiAlN Speed
Structural Steel
39 35 32
34 31 28
0.30 0.28 0.25
0.45 0.40 0.36
0.48 0.43 0.40
0.50 0.48 0.45
B
P
A36, A285, A516, etc.
BORING
Notch Point® and 150° Structural Steel Inserts Super Cobalt
Speed (M/min) - Mist Coolant
Feed Rate (mm/rev) by Diameter
C
0 series 3 series (12.98 mm - 17.67 mm) (17.53 mm - 24.40 mm) (24.41 mm - 35.06 mm) (34.37 mm - 47.82 mm) 1 series 2 series
Hardness (BHN) 100 - 150 150 - 250 250 - 350
ISO Material
AM200® Speed TiAlN Speed
REAMING
Structural Steel
39 35 35
34 31 28
0.25 0.23 0.20
0.30 0.28 0.25
0.36 0.30 0.28
0.45 0.40 0.36
P
A36, A285, A516, etc.
GEN2 T-A Inserts Super Cobalt
D
Speed (M/min) - Mist Coolant
Feed Rate (mm/rev) by Diameter
BURNISHING
0 series
1 series
2 series
3 series
Hardness (BHN) 100 - 150 150 - 250 250 - 350
ISO Material
AM200® Speed
(12.98 mm - 17.67 mm)
(17.53 mm - 24.40 mm)
(24.41 mm - 35.06 mm)
(34.37 mm - 47.82 mm)
Structural Steel
39 35 35
0.25 0.23 0.20
0.30 0.28 0.25
0.36 0.30 0.28
0.46 0.40 0.36
P
A36, A285, A516, etc.
GEN2 T-A Inserts Carbide C1 (K35)
E
Speed (M/min) - Mist Coolant
Feed Rate (mm/rev) by Diameter
THREADING
0 series
1 series
2 series
3 series
Hardness (BHN) 100 - 150 150 - 250 250 - 350
ISO Material
AM300® Speed
(12.98 mm - 17.67 mm)
(17.53 mm - 24.40 mm)
(24.41 mm - 35.06 mm)
(34.37 mm - 47.82 mm)
Structural Steel
50 47 43
0.20 0.15 0.13
0.28 0.25 0.23
0.38 0.33 0.30
0.43 0.38 0.33
P
A36, A285, A516, etc.
X
SPECIALS
NOTE: The speeds and feeds listed above are based on a rigid setup using air mist through tool coolant. Speed may be increased up to 50% if using high pressure flood or through coolant. NOTE: If drilling dry without coolant, speed must be reduced significantly based on setup, drill depth, and material hardness. Up to 50% speed and feed reducƟon may be necessary in these types of applicaƟons. Contact the ApplicaƟon Engineering department for assistance. email: engineering.eu@alliedmachine.com
A91: 64
www.alliedmachine.com | +44 (0) 1384 400 900 | enquiries.eu@alliedmachine.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online